TM 5-5420-234-14&P
4-71. CAB CONTROL BOX ASSEMBLY REPAIR (MODEL A ONLY) (continued).
NOTE
30
29
The "NC" switch ter-
minals are not used.
(12) Connect four spade connec-
tors (32) to two switches (33
31
and 34).
(13) Connect four spade connec-
tors (29) to two circuit
breakers (30 and 31).
32
34
33
32
(14) Install terminals (28) in three connectors (20, 21, and 26).
NOTE
Connectors should be installed with notch
facing top of control box.
24 23
(15) Install new gasket (27) and connector (26) in cab control
26
box (10) with four screws (25), new lockwashers (24) and
27
nuts (23).
NOTE
18
17
Install cable ties as required.
28
(16) Install two new gaskets (22) and connectors (20 and 21) in
cab control box (10) with eight screws (19), new lock-
washers (18), and nuts (17).
20 28
21
22
25
19
10
4-592
Change 1