TM 5-5420-234-14&P
4-61. MAIN JUNCTION BOX REPAIR (MODEL A ONLY) (continued).
(9) Install jumper wire (14) on terminal no. 24 (13) and terminal no. 26 (15).
(10) Install jumper wire (12) on terminal no. 22 (11) and terminal no. 24 (13).
(11) Install jumper wire (10) on terminal no. 20 (9) and terminal no. 22 (11).
(12) Install jumper wire (7) on terminal no. 18 (8) and terminal no. 20 (9).
(13) Install jumper wire (4) on terminal no. 14 (5) and terminal no. 16 (6).
(14) Install jumper wire (1) on terminal no. 2 (2) and terminal no. 7 (3).
4
1
3
2
5
6
8
7
15
9
10
11
13
14
12
d. Follow-on Maintenance:
Install hook arm down proximity switch harness in junction box (para 4-94).
Install right hand linking harness in junction box (para 4-88).
Install oil temperature sensor and harness in junction box (para 4-87).
Install main junction box harness (rear) in junction box (para 4-92).
Install main junction box harness (front) in junction box (para 4-85).
Install main junction box harness (24 pin) in junction box (para 4-84).
Install main frame valve (unload) harness in junction box (para 4-83).
Install left hand linking harness in junction box (para 4-80).
Install hook arm valve (unload) harness in junction box (para 4-79).
Install hook arm valve (load) harness in junction box (para 4-78).
Install hand-held spotlight harness in junction box (para 4-77).
Install free flow valve harness in junction box (para 4-76).
END OF TASK
4-560
Change 1