TM 9-2320-279-34-2
Winch Maintenance Instructions (Cont)
16-5. SELF-RECOVERY WINCH COUNTERBALANCE VALVE REMOVAL/INSTALLATION.
This task covers:
a. Removal
c. Follow-on Maintenance
b. Installation
INITIAL SETUP
Models
All
Test Equipment
None
Special Tools
None
Supplies
None
Personnel Required
MOS 63W, Wheel vehicle repairer
References
None
Equipment Condition
TM or Para
Condition Description
TM 9-2320-279-20 Self-recovery winch and
brackets removed.
Special Environmental Conditions
None
General Safety Instructions
None
Level of Maintenance
Direct Support
a. Removal.
(1) Loosen fitting (1).
(2) Remove three screws (2) and counterbalance valve (3) from hydraulic motor (4).
b. Installation.
(1) Install counterbalance valve (3) and three screws (2) on hydraulic motor (4).
(2) Tighten three screws (2).
(3) Tighten fitting (1).
c. Follow-on Maintenance. Install self-recovery winch and brackets (TM 9-2320-279-20).
END OF TASK
16-14