TM 9-2320-279-34-1
Transmission Maintenance Instructions (Cont)
7-9. TORQUE CONVERTER HOUSING REMOVAL/REPAlR/INSTALLATlON (CONT).
(20)
(21)
(22)
Soldier A and Soldier B position and
hold torque converter housing (1) on
rim.
Soldier A and Soldier B remove front
support assembly (3).
Remove gasket (31) from torque
converter housing (1).
(23)
Remove bearing (32) from ground
sleeve bore (33).
c.
Cleaning/Inspection.
WARNING
Adhesives, solvents, and sealing compounds
can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To
avoid injury or death, keep away from open
fire and use in well-ventilated area. If
adhesive, solvent, or sealing compound gets
on skin or clothing, wash immediately with
soap and water.
(1)
Clean all metallic parts with
drycleaning solvent and inspect for
damage. If there is damage, replace
parts.
(2)
Converter bypass valve spring, lockup
shift valve spring, and main pressure
regulator valve spring must be replaced
if load-height specifications, listed in
Table 7-1, are not met.
Table 7-1.
Valve Spring Load-Height Specifications
Spring
Length Without Load
Length Under Load
Load
Converter
2.65 in.
1.62 in.
21.1 to 23.3 lb
bypass valve
(67.3 mm)
(41.2 mm)
(93.9 to 103.6 Nm)
Lockup shift
3.22 in.
1.8 in.
22.10 to 23.50 lb
valve
(81.8 mm)
(45.7 mm)
(98.3 to 104.5 Nm)
Main regulator
3.94 in.
2.64 in.
82.4 to 86.6 lb
valve
(100.1 mm)
(67.1 mm)
(366.5 to 385.2 Nm)
7-60
Change 3