TM 5-5420-234-14&P
4-28. BAP REAR GUIDE REPAIR (continued).
(5) Remove cotter pin (11) and washer (12) from pivot pin (13). Tap pivot pin (13) out of BAP frame (14).
Discard cotter pin.
(6) Remove screw (15), rubber bumper (16), two spacers (17), washer (18), and self-locking nut (19) from
reaction bracket (20) and lock bracket (8). Discard self-locking nut.
(7) Remove reaction bracket (20) and washer (21) from lock bracket (8).
(8) Remove spring pin (22) from latch handle (23). Remove latch handle (23) from latch pin (24). Discard
spring pin.
(9) Remove latch pin (24) from frame (14).
(10) Remove spring (25) from latch pin (24).
8
26
19
18
13
12
21
14
20
17 16
17
15
11
25
24
22
b. Cleaning and Inspection.
23
WARNING
Drycleaning solvent is TOXIC and flammable. Wear protective goggles and gloves;
use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and DO
NOT breathe vapors. Keep away from heat or flame. Never smoke when using
drycleaning solvent; the flashpoint for Type II is 140 degrees F (60 degrees C), and for
Type III it is 200 degrees F (93 degrees C). Failure to follow this warning may result
in death or injury to personnel.
(1) Clean all parts with drycleaning solvent and rag.
(2) Inspect all parts for damage. Replace damaged parts as necessary.
4-440