TM 9-2320-279-34-1
Transfer Case Maintenance Instructions (Cont)
a.
Removal.
(1)
Disconnect lubrication hose (1) from fitting (2).
(2)
Remove four screws (3) and lockwashers (4).
(3)
Remove lubrication pump (5) from bearing cover (6).
(4)
Remove fitting (2) from lubrication pump (5).
(5)
Remove plug (7).
b. Installation.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
(1)
Coat pipe threads of fitting (2) with pipe thread sealing compound and install fitting in
lubrication pump (5).
(2)
Coat pump mounting surface of bearing cover (6) with adhesive.
(2.1) Apply sealing compound to threads of four screws (3).
(3)
Mount lubrication pump (5) on bearing cover (6) with four screws (3) and lockwashers (4).
Tighten screws to 15 lb-ft (20 Nm).
(4)
Connect lubrication hose (1) to fitting (2).
(5)
Coat threads of plug (7) with pipe thread sealing compound and install plug.
c.
Follow-on Maintenance. None.
END OF TASK
C h a n g e 3 8 - 53