TM 9-2320-279-34-1
Transfer Case Maintenance Instructions (Cont)
8-14.
LOCKOUT SHIFT CHAMBER REMOVAl/REPAIR/INSTALLATlON (CONT).
c.
Cleaning/Inspection.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. lb avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
(1)
Clean all metal parts in drycleaning solvent.
(2)
Inspect all metal parts for damage.
(3) Replace damaged parts.
d. Assembly.
(1)
Install diaphragm (1), guide (2), and
nut (3) on air pressure plate (4).
(2)
Install seal (5) and pilot ring (6) in rear of chamber body (7).
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give
off harmful vapors, and are harmful to skin and clothing. To avoid
injury or death, keep away from open fire and use in well-ventilated
area. If adhesive, solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and water.
(3)
Coat rear of chamber body (7) with adhesive.
8-50 Change 3