TM 9-2320-279-34-1
Change 5
6-14.13
Electrical System Maintenance Instructions (Cont)
NOTE
Capacitor wires have three different lengths.
Wires should be routed accordingly.
(23)
Install three wires (51) on regulator
studs (36) with nuts (52).
(24)
Secure three wires (51) to slip ring end
housing (6) with screw (53), lockwasher
(54), and clip (55).
(25)
Position spacer (56), key (57), cooling
plate (58), pulley (59), and locknut (60)
on shaft (61). Do not tighten.
NOTE
Vise is used to hold pulley securely for step
(26).
(26)
Position alternator (62) in vise.
(27)
Tighten locknut (60) to 70-80 lb-ft
(95-108 N·m).
(28)
Remove alternator (62) from vise.