Winches, Cranes, and Power Takeoff (PTO) Maintenance Instructions (Cont)
a. Removal.
(1)
(1.1)
(2)
(3)
(4)
(5)
.
Loosen screws enough to remove guard.
.
Tag and mark hose before disconnecting.
Loosen two screws (1), lockwashers (1.11, and washers (1.2) and remove guard (2).
Remove four screws (2.11, lockwashers (2.21, two plates (3), and hose (4).
Remove preformed packing (5) from hose (4).
Remove four screws (6), lockwashers (7), two plates (8), and hose (9).
Remove preformed packing (10) from hose (9).
Disconnect three hoses (11, 12, and 13).
NOTE
On some models, electrical leads are connected by an electrical plug and on others by
electrical terminals, lockwashers, and screws. If connected by an electrical plug, perform
step (6). If connected by terminals, lockwashers, and screws, perform step (6.1).
(6)
Disconnect electrical plug (14).
(6.1) Remove two screws (15), lockwashers (16), and wires (17).
TM 9-2320-279-20-2
NOTE
.
Trucks with guard, perform steps (1) through (6). Trucks without guard, perform
steps (1.1) through (6).
Change 2
17-133