TM 9-2320-279-20-2
Change 4
13-37
Stewing System Maintenance Instructions (Cont)
13-10. HYDRAULIC RESERVOIR TOP PLATE AND GASKET REMOVAL/INSTALLATION
(CONT).
(10)
Remove 20 locknuts (14)
from top plate (15).
(11)
Remove top plate (15) from
hydraulic reservoir (2).
(12)
Remove gasket (16).
b. Installation.
(1)
Install gasket (1) on top of
hydraulic reservoir (2).
(2)
Install top plate (3) with 20
locknuts (4).
(2.1) Tighten locknuts (4) to 45 to 55 lb-in
(5 to 6 N·m) in sequence shown.
(2.2) Tighten locknuts (4) to 60 to 65 lb-in
(7 to 7.5 N·m) in sequence shown.