TM 5-5420-234-14&P
4-85. MAIN JUNCTION BOX HARNESS (FRONT) REPLACEMENT (MODEL A ONLY)
(continued).
(2) Connect connector P3 (17) to main junction box harness (18).
(3) Install wire no. 9 (15) on terminal no. 9 (16), wire no. 5 (13) on terminal no. 5 (14) and wire no. 6 (12)
on terminal no. 6 (9).
(4) Install wire no. 31 (10) on terminal no. 31 (11), wire no. 6 (8) on terminal no. 6 (9), wire no. 29 (6) on
terminal no. 29 (7) and wire no. 30 (4) on terminal no. 30 (5).
(5) Close junction box cover (3) and tighten four screws (2).
1
2
3
(6) Close hydraulic cabinet cover (1).
c. Follow-on Maintenance:
Connect batteries (TM 9-2320-279-20).
END OF TASK
4--639
Change 1
4 639