TM 5-5420-234-14&P
Table 3-1. Operator/Crew Troubleshooting (continued)
Malfunction
Test or Inspection
Corrective Action
5. BAP WINCH ASSEMBLY WILL NOT LIFT LOAD OR OPERATES SLOWLY.
2
1
3
4
6
7
5
NOTE
Perform the following check by operating the CBT/winch with a load
in place.
Step 1.
With load attached to hook (1) on winch cable (2), set BAP winch switch (3) on remote
control unit (4) to IN.
If cable will not lift the load or operates slowly, go to Step 2.
Step 2.
Check for any binding of or obstructions to winch cable (2) and/or loose or missing winch
mounting hareware (5, 6, and 7).
Step 3.
Check fluid level in BAP winch (Appendix G). Notify Unit maintenance if fluid level is low.
Step 4.
Check for leaks in the BAP or for other obvious damage to winch hydraulic lines and fittings.
If leaks or damage are noted, notify Unit maintenance.
If no leaks or damage are noted, go to Step 5.