TM 5-5420-234-14&P
Table 3-1. Operator/Crew Troubleshooting (continued)
Malfunction
Test or Inspection
Corrective Action
3. BAP WINCH ASSEMBLY WILL NOT WIND OUT.
5
1
3
2
4
Step 1.
Make sure BAP winch assembly switch (1) on remote control unit (2) is set to OUT.
Step 2.
Check for leaks in BAP winch hydraulic lines and fittings.
If leaks are noted, notify Unit maintenance.
If no leaks are noted, go to Step 3.
Step 3.
Make sure BAP winch hydraulic lines quick-disconnect connectors (3) are properly connected
to CBT hydraulic system quick-disconnect connectors (4).
Disconnect and reconnect quick-disconnect connectors (3).
If winch still does not work, go to Step 4.
Step 4.
Check remote control at receptacle (5) on opposite side of Transporter.
If winch still does not work, notify Unit maintenance.