TM 9-2320-279-34-1
Electrical System Maintenance Instructions (Cont)
(12) Connect lead
(13)
(14)
(32) to low engine oil
switch (33) with screw (34).
Connect two wires (35) to low oil
pressure switch (36).
Connect wire (37) to oil pressure
sending unit (38) with lockwasher (39)
and nut (40).
(15)
Connect wire (41) and harness wires (42 and 44) to starter terminal (45) with lockwasher (46)
and nut (47).
(16)
Connect wire (48) to starter solenoid terminal (49) with washer (50) and nut (51).
(17)
Connect two wires (52 and 53) to starter solenoid terminal (54) with nut (55) and washer (56).
Change 3
6-99