TM 9-2320-279-20-3
Chemical, Biological, and Radiological (CBR) Equipment Maintenance Instructions (Cont)
26-3. M-13 DECONTAMINATION UNIT REMOVAL/INSTALLATION (CONT).
(6) Install decontamination unit (14) and
tighten strap (5).
c. Follow-on Maintenance. None.
END OF TASK
26-4. GAS PARTICULATE FILTER UNIT (GPFU) REMOVAL/INSTALLATION.
This task covers:
a. Removal
c. Follow-on Maintenance
b. Installation
INITIAL SETUP
Models
Equipment Condition
All
TM or Para
Condition Description
Test Equipment
Para 7-91
Batteries disconnected.
None
Special Tools
Special Environmental Conditions
None
Contaminated filters shall be placed in
Supplies
double-lined plastic bags, moved swiftly away
from worksite, temporarily stored, and disposed
Tags, identification, Item 48, Appendix C
Compound, sealing, pipe thread, Item 18,
of in accordance with local SOP.
Appendix C
Decontamination operations shall be performed
according to TM 3-220.
Personnel Required
General Safety Instructions
MOS 63S, Heavy wheel vehicle mechanic (2)
After nuclear, biological, or chemical exposure
References
of vehicle, air filter shall be handled with
TM 3-220
extreme caution. Wear protective clothing
TM 10-277
during this operation (TM 10-277).
2 6 - 14