TM 9-2320-279-20-3
Filter-Separator Maintenance Instructions (Cont)
23-4.1 FILTER-SEPARATOR REMOVAL/REPAIR/INSTALLATION (M978) (MODEL B)
(CONT).
(17)
Install ten tee screws (30), roll
pins (31), washers (32), and nuts (33).
Tighten to 105 lb-ft (142 Nm).
WARNING
Adhesives, solvents, and sealing
compounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. To avoid injury or death,
keep away from open fire and use in
well-ventilated area. If adhesive, solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
(18)
Apply pipe thread sealing compound to
threads of plug (34) and install in
cover (29).
e. Installation.
(1)
Install two coupling gaskets (1
and 2) on two pipes (3 and 4).
(2)
Install three brackets (5) on
grating (6) with three
screws (7), brackets (8), and
locknuts (9).
(3)
Soldier A guides
filter-separator (10) in through
top access opening of pump
module while Soldier B operates
suitable lifting device.
23-36
Change 3