TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
17. BAP WINCH DOES NOT OPERATE (MODEL B ONLY) (continued).
HYDRAULICCABINET
COVER
CONTINUITY TEST
CAUTION
Electrical power must be shut off
be checked. Failure to comply with
this caution may result in damage
to test equipment or electrical sys-
tem.
(1) Remove six screws and flatwashers
from hydraulic cabinet cover and
remove cover.
(2) Remove right hand (J3) and left hand
WINCH OUT
(J4), 40-pin connectors from digital
contoller.
VALVE
POSITION 1
NOTE
POSITION 2
A reading of infinity indicates an
J3
POSITION
open circuit.
35
POSITION 5
controller wiring harness connector,
POSITION
33
(P2), position "2", and (J4), position
(5) Connect multimeter between (P2),
position "3", and (J4), position "35".
POSITION
Check multimeter for continuity.
1
(6) Connect multimeter between (P2),
position "4", and (J4), position "33".
POSITION
Check multimeter for continuity.
J4
35
(7) Connect multimeter between (J3),
connector, position "1". Check
multimeter for continuity.
(8) Connect multimeter between (J3),
P2
connector, position "2". Check
multimeter for continuity.
POSITION 2
POSITION 4
POSITION 3
Change 1
4-49395
3- 0. 5