TM 9-2320-279-34-1
Change 5
6-14.5
Electrical System Maintenance Instructions (Cont)
CAUTION
Do not remove lower bushing from negative
rectifier. Failure to comply may damage
bushing.
(27)
Remove lower mounting screw (65),
lockwasher (66), washer (67), plastic
washer (68), negative rectifier (45) with
bushing (69), and two washers (70) from
slip ring end housing (25).
(28)
Position slip ring end housing (25) in
press and remove bearing (71).
(29)
Remove bushing (72) from slip ring end
housing (25).
(30)
Position drive end housing (38) and
rotor assembly (39) in press with
threaded end of shaft (17) pointing
upward.
CAUTION
Protect rotor assembly from striking floor
while pressing from drive end housing.
Failure to comply may result in damage to
rotor assembly.
(31)
Press rotor assembly (39) out from drive
end housing (38).