TM 9-2320-279-34-3
Power Takeoff (PTO) and Hydraulic Pump Maintenance Instructions (Cont)
19-2. POWER TAKEOFF (PTO) REPAIR (CONT).
a.
Disassembly
NOTE
There are two models of power takeoff (PTO)
units. Model B has two pipe plug adapters,
one pipe plug, and no cover plate.
(1)
Remove pipe plug (1), setscrew (2), and
fitting (3) from power takeoff (PTO)
housing (4).
NOTE
Skip step (2) and do step (2.1) for Model B.
(2)
Remove four screws (5), cover plate (6),
and gasket (7).
(2.1) Remove two pipe plugs (1.1) and pipe
plug adapters (1.2).
(3) Remove screw (8).
NOTE
Mark open-end bearing cover and power
takeoff (PTO) housing.
(4)
Remove four screws (9), open-end
bearing cover (10), and gasket (11) from
power takeoff (PTO) housing (4).
(5)
Remove oil seal (12) and breather (13)
from open-end bearing cover (10).
19-2 Change 3