CAUTION
Do not pinch or pull coupling
gaskets off-center while installing
coupling halves. If coupling gaskets
are damaged or moved out of
position, piping connections will
leak.
(16) Install two coupling halves (23)
with screws (24) and nuts (25).
NOTE
Loosen pipe connector at next
connection.
(17) Position coupling gasket (26)
over ends of discharge
eIbow (12) and discharge
pipe (27).