TM9-2320-279-20-3
Filter-Separator Maintenance Instructions (Cont)
b. Installation.
WARNING
Adhesives, solvents, and sealing
compounds can burn easily, can give off
harmful vapors. and are harmful to skin
and clothing. To avoid injury or death,
keep away from open fire and use in
weIl-ventilated area. If adhesive. solvent,
or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
(1)
(2)
Apply pipe thread sealing compound to
threads of pipe nipple (1) and install V15
DRAIN VALVE (2) and bracket (3).
Apply pipe thread sealing compound to
pipe threads ofelbow (4) and install on
bracket (3).
Apply pipe thread sealing compound to
pipe threads of adapter (5) and install in
Install tube (6) on elbow (1).
(3)
V15 DRAIN VALVE (2).
(4)
(5)
(6)
Position V15 DRAIN VALVE (2) on
grating (7).
Connect tube (8) to adapter (5).
Hold bracket (3) in place and install with
bracket (9), screw (10). and locknut (11).
Turn V15 DRAIN VALVE handle (12)
clockwise to closed position.
(7)
(8)
c. Follow-on Maintenance.
(1) Recirculate fuel (TM 9-2320-279-10).
(2) Turn V15 DRAIN VALVE handle
counterclockwise to open position and
check that fuel drains.
(3) Turn VI5 DRAIN VALVE handle
clockwise to closed position.
(4) Check that fuel stops draining and there
are no leaks.
(5) Close pump module rear doors
(TM 9-2320-279-10).
END OF TASK
23-3