TM 5-5420-234-14&P
4-96. PROXIMITY SWITCH REPLACEMENT/ADJUSTMENT (MAIN FRAME DOWN)
(continued).
(12) Position mainframe junction box cover (2) on junction box (3) and tighten four screws (1).
c. Adjustment.
3
1
2
NOTE
Proximity switch mounting plate and middle frame have slotted holes to aid
in adjustment.
(1) Adjust height between top of proximity switch (1) and top of target plate (2). Height should be .38 in.
.01 in. (9.65 mm .25 mm).