TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
19. BAP WINCH DOES NOT WIND IN (MODEL B ONLY) (continued).
CAUTION
Electrical power must be shut off
be checked. Failure to comply with
this caution may result in damage
to test equipment or electrical sys-
tem.
NOTE
A reading of infinity indicates an
open circuit.
WINCH IN VALVE
"1" and position " 2" on winch in valve
continuity.
POSITION 1
POSITION 2
Change 1
4-4-14.3