TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
19. BAP WINCH DOES NOT WIND IN (continued).
5.
KNOWN INFO
TEST OPTIONS
Winch inoperative at both
remote locations.
sured between the
No power at main
remote control harness,
REASON FOR QUESTION
junction box terminal
between connectors P8
If there is an open circuit
strip.
and P9?
in the remote control
Remote control OK.
cable, the signal from the
POSSIBLE PROBLEMS
remote control unit will
not reach the linking
Remote control cable
harness or the main
faulty.
junction box.
Replace remote
NO
control cable.
MODEL A, fault not
corrected. Notify
YES
supervisor.
MODEL B, Go to
YES
Step 9.
4-408
Change 1