TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
16. MAIN FRAME, HOOK ARM, AND WINCH DO NOT OPERATE (continued).
CONTINUITY TEST
CAUTION
Electrical power must be shut off
be checked. Failure to comply
with this caution may result in dam-
age to test equipment or electrical
system.
(1) Disconnect remote control cable from
P9
components.
NOTE
A reading of infinity indicates an open
circuit.
of wire and check multimeter for
continuity. Check for continuity
P8
between position C on chassis end
and position L on remote control end.
REMOTE CONTROL CABLE
position J on chassis end and
position E on remote end.
4-363