TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
14. MAIN FRAME DOES NOT UNLOAD IN MANUAL MODE (MODEL A ONLY)
(continued).
MAIN FRAME UNLOAD
CONTINUITY TEST
CAUTION
Electrical power must be shut off
be checked. Failure to comply
with this caution may result in dam-
age to test equipment or electrical
system.
(1) Remove connector from the hook arm
UNLOAD solenoid.
NOTE
A reading of infinity indicates an
open circuit.
Junction box terminal 19 is con-
nected to one side of the solenoid;
terminal 20 is connected to the
other side.
SOLENOID
CONNECTOR,
of wire, and check multimeter for
POSITION 1
continuity. Check for continuity
position 1, and terminal strip, position
19.
between position 2 in the connector
and terminal strip, position 20.
SOLENOID
CONNECTOR,
POSITION 2
4-279
Change 1