TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
12. HOOK ARM DOES NOT UNLOAD IN MANUAL MODE (MODEL A ONLY) (continued).
CONTINUITY TEST
(1) Open hydraulic cabinet cover.
(2) Loosen four screws on main junction
box cover and open cover.
CAUTION
Electrical power must be shut off
be checked. Failure to comply with
this caution may result in damage
to test equipment or electrical sys-
tem.
(3) Remove connector from the hook arm
UNLOAD solenoid.
NOTE
A reading of infinity indicates an
open circuit.
HOOK ARM UNLOAD
Junction box terminal 13 is con-
nected to one side of the sole-
noid; terminal 14 is connected
to the other side.
SOLENOID
of wire, and check multimeter for
CONNECTOR,
POSITION 2
continuity. Check for continuity
position 1, and terminal strip, position
13.
between position 2 in the connector
and terminal strip, position 14.
SOLENOID
CONNECTOR,
POSITION 1
Change 1
4-227