TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
4.
MAIN FRAME WORKLIGHT DOES NOT OPERATE (MODEL A ONLY) (continued).
MAIN FRAME
JUNCTION BOX
MAIN FRAME
TERMINAL STRIP, JUNCTION BOX
POSITION 5
TERMINAL STRIP,
POSITION 7
CONTINUITY TEST
CAUTION
Electrical power must be shut off
be checked. Failure to comply with
this caution may result in damage
to test equipment or electrical sys-
tem.
(1) Set multimeter to ohms position.
NOTE
A reading of infinity indicates an
open circuit.
of wire, and check multimeter for
WORKLIGHT
CONNECTORS
between terminal strip position 7 and
the end of one wire, and between
terminal strip position 5 and the end of
the other wire.
NOTE
Any reading besides infinity indi-
cates a grounded wire.
of wire and connect to chassis ground.
4-4-91
94.5
Change 1