TM 5-5420-234-14&P
Table 2-1. Operator/Crew Preventive Maintenance Checks and Services (PMCS) (continued)
Item To
Not Fully Mission
Item
Check/
Interval
Procedure
Capable If:
No.
Service
22
During
Remote Control
g. Position remote control MAIN
Unit (continued)
FRAME switch (10) to UNLOAD and
release when main frame is extended fully.
Make sure main frame extends fully.
8
11
10
h. Position HOOK ARM switch (8) to
UNLOAD and release when winch cable
hook can be reached from the ground.
WARNING
Be careful when handling the winch
cable. Always wear leather gloves
and make sure cut ends are taped.
Make sure cut ends of cable on
winch assembly are securely fas-
tened down. Failure to heed this
warning may result in injury to
personnel.
NOTE
Have an assistant maintain tension
on cable.
i. Position remote control WINCH
switch (11) to OUT and release when cable
has been wound out about 8 feet (2.4 m).
Winch cable should wind out.
2-27