T M 9 - 2 3 2 0 - 2 7 9 - 3 4 -1
Electrical System Maintenance Instructions (Cent)
6 - 1 2 . C R A N E O V E R L O A D S E N S O R S W I T C H E S R E M O V A L / I N S T A L L A T I O N ( M 9 7 7 , M 9 8 5)
.
(3)
(4)
Tighten nut (6) and jamnut (7) until one screw
thread is below surface of nut (6).
Adjust nut (8) and jamnut (9) until reduced
overload switch (1) is 1/4 in. (6 mm) from switch
sensing plate (10).
N O T E
Remove clips and plastic cable
ties.
(2) Remove four screws (3) and
mounting clamp (4) from
mast (5).
(3) Remove mast overload
switch (6) from mounting
clamp (4).
e . M a s t O v e r l o a d S w i t c h
R e m o v a l ( M 9 7 7 o n l y ) .
N O T E
Tag and mark wires before
removal.
(1) Disconnect three wires (1)
at connectors (2).
6-68