TM 9-2320-279-34-3
22-52.4
Change 4
M978 Tanker Maintenance Procedures Instructions (Cont)
22-10.1 V1 EMERGENCY VALVE REPAIR (MODEL B) (CONT).
b. Cleaning/Inspection.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
(1)
Clean all metal parts with dry cleaning solvent.
WARNING
Compressed air used for cleaning purposes will not exceed 30 psi (207 kpa). Use
only with effective chip guarding and personal protective equipment goggles,
shield, and gloves.
(2)
Use clean cloth and compressed air to dry metal parts cleaned with dry cleaning solvent.
(3)
Inspect all metal parts for bends, breaks, cracks, and sharp edges.
(4)
Replace damaged parts.
c. Assembly.
(1)
Install retaining ring (1), retaining
gland (2), and retaining ring (3) on
camshaft (4).
(2)
Install preformed packing (5) in valve
body (6).
(3)
Install camshaft (4) in valve body (6).
(4)
Install cam (7) and retaining ring (8) on
camshaft (4).