TM 9-2320-279-34-1
Transfer Case Maintenance Instructions (Cont)
8-2. TRANSFER CASE REMOVAL/INSTALLATION (CONT).
(10)
Install shift cable bracket (17) with two
screws (18) and lockwashers (19).
WARNING
Adhesives, solvents, and sealing compounds
can burn easily, can give off harmful vapors,
and are harmful to skin and clothing. To avoid
injury or death, keep away from open fire and
use in well-ventilated area. If adhesive,
solvent, or sealing compound gets on skin or
clothing, wash immediately with soap and
water.
(11)
Apply silicone adhesive-sealant to end
and splined surface of output shaft (20).
Apply sealing compound to threads of
two screws (21).
NOTE
Retaining screws may be either grade 5 or
grade 8. Torque screws accordingly,
(12)
Install retainer washer (22) and two
screws (21). Tighten grade 8 screws to
88 lb-ft (119 Nm). Tighten grade 5
screws to 60 lb-ft (81 Nm).
(13)
Slide shift cable (23) in slot in shift cable bracket (17). Tighten two nuts (24), one on each side of
shift cable bracket slot.
8-8
Change 3