T M 9 - 2 3 2 0 - 2 7 9 - 3 4 - 1
Electrical System Maintenance Instructions (Cont)
6 - 1 1 . J U N C T I O N B O X A N D C O N N E C T O R R E M O V A L / R E P A I R / I N S T A L L A T I O N ( M 9 7 7 , M 9 8 5 )
(CONT).
b . D i s a s s e m b l y .
(1) Remove cap (1).
(2) Remove four screws (2),
lockwashers (3), washers (4), and
cover (5) from box (6).
N O T E
Tag and mark wires before removing or
disconnecting.
(3) Remove two screws (7) and three
wires (8).
(4) Remove sealnut (9), lockwasher (10),
switch (11), and nut (12).
N O T E
Connector must be removed
with cable module.
(5) Remove nut (13) and
lockwasher (14).
(6) Remove nut (15),
lockwasher (16), and
connector (17).
6-58