Step 4.
Check main hydraulic pressure adjustment (para 17-31 for M977 and M985) (para 17-31.1
for M984E1).
If main hydraulic pressure cannot be adjusted, repair crane control valve
(para 17-28 for M977 and M985) (para 17-28.4 for M984E1).
Step 4.1
Check for contaminated or damaged boom relief valve.
Remove, clean, inspect, and install boom relief valve (para 17-32.1).