TM 9-2320-279-20-3
M978 Tanker Maintenance Instructions (Cont)
25-8. FLOWMETER STRAINER ASSEMBLY REMOVAL/INSTALLATION (CONT).
WARNING
Adhesives, solvents, and sealing compounds can
burn easily, can give off harmful vapors, and are
harmful to skin and clothing. To avoid injury or
death, keep away from open fire and use in
well-ventilated area. If adhesive, solvent, or
sealing compound gets on skin or clothing, wash
immediately with soap and water.
(3)
(4)
(5)
(6)
25-42
Apply silicone adhesive-sealant on gasket (6)
and install gasket and housing (3) on meter (7)
with four screws (8) and washers (9).
Install strainer (10) in
strainer housing (3).
Apply silicone
adhesive-sealant on
gasket (11) and install
gasket and elbow (12) on
housing (3) with four
screws (13) and
washers (14).
Do not tighten screws (13).