TM 9-2320-279-20-3
Hydraulic System Maintenance Instructions (Cont)
(3)
Remove three adapters (9) and
preformed packings (10) from valve (6).
b .
Installation.
NOTE
There are two kinds of valves. Model A
uses spacers and 3 in. (76 mm) mounting
screws. Model B does not use spacers and
has 2 in. (51 mm) mounting screws. Both
valves are removed the same way.
(1)
Install three preformed packings (1)
and adapters (2) in valve (3).
NOTE
Spacers mount between valve and bracket
on Model A only.
(2)
Install valve (3) and two spacers (4)
with two screws (5), lockwashers (6),
and nuts (7).
(3)
Connect three hoses (8, 9, and 10).
c.
Follow-on Maintenance.
(1) Fill hydraulic reservoir
(LO 9-2320-279-121.
(2) Check connections for leaks.
(3) Install stowage box (M978) (para 16-34).
(4) Connect batteries (para 7-91).
END OF TASK
Change 3
19-11