TM 9-2320-279-20-2
b.
Cab and Body Maintenance Instructions (Cont)
(5) Disconnect fitting (9) and remove hose (2) from swivel fitting (10).
(6) Remove hose (2) from pump module (11).
Installation.
WARNING
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
(1) Apply lubricating sealing compound to threads of swivel fitting (1).
(2) Position hose (2) on pump module (3) and connect at fitting (1).
16-180