Change 8
TM 9-2320-279-10-1
3-18
Troubleshooting Malfunctions (Cont)
3-3. TROUBLESHOOTING SYMPTOMS (CONT).
Table 3-2. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
AIR SYSTEM
1. BUZZER SOUNDS AND AIR INDICATOR IS LIT.
Step 1.
Check air pressure gage.
If gage shows 75 psi (517 kPa) or more, but buzzer
and light are still on, notify organizational
maintenance.
Step 2.
Check to make sure all four air reservoir petcocks are closed.
Close all petcocks.
If buzzer and light are still on, go to Step 3.