TM 9-2320-279-10-1
Troubleshooting Malfunctions (Cont)
Table 3-2. Troubleshooting (Cont)
Malfunction
Test or Inspection
Corrective Action
ENGINE (CONT)
2.
CRANKS BUT FAILS TO START (CONT).
Step 3.
Check air filter restriction indicator.
If indicator shows yellow, but engine still will not
start, notify organizational maintenance.
If indicator shows red and/or VACUUM INCHES H2O
window shows 18 or more, clean air filter (para 3-8).
If indicator still shows red after cleaning air filter,
notify organizational maintenance.
Change 5
3-5