TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
22. PRESSURE SENSORS, PS1 / PS2, INOPERATIVE, ERROR CODE 26 AND 27,
(MODEL B ONLY) (continued).
HYDRAULICCABINET
COVER
CONTINUITY TEST
CAUTION
Electrical power must be shut off
be checked. Failure to comply with
this caution may result in damage
to test equipment or electrical sys-
tem.
(1) Remove six screws and flatwashers
from hydraulic cabinet cover and
remove cover.
(2) Remove left hand (J4), 40-pin
connector from digital contoller.
NOTE
POSITION
33
A reading of infinity indicates an
open circuit.
controller wiring harness connector,
(P2), position "2", and (J4), position
POSITION
J4
1 POSITION
(5) Connect multimeter between (P2),
35
position "3", and (J4), position "35".
(6) Connect multimeter between (P2),
position "4", and (J4), position "33".
P2
POSITION 4
POSITION 2
POSITION 3
4-41-4.45
4 4 31
Change 1