4-12. UNIT TROUBLESHOOTING (continued).
14. MAIN FRAME DOES NOT UNLOAD IN MANUAL MODE (MODEL A ONLY)
(continued).
CONTINUITY TEST
CAUTION
Electrical power must be shut off
be checked. Failure to comply
with this caution may result in dam-
CAB CONTROL
9-PIN LINKING
age to test equipment or electrical
HARNESS
BOX CONNECTOR
system.
(J2)
CONNECTOR (J5)
(1) Disconnect cab control box connector
(P2) from cab control box.
NOTE
A reading of infinity indicates an open
circuit.
(3) Connect multimeter between (9-pin)
linking harness connector (J5),
position A, and cab control box
connector (J2), position F. Check
NOTE
Any reading besides infinity indicates
a grounded wire.
CAB CONTROL
BOX CONNECTOR
(P2)
of wire and connect to chassis
ground.