TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
13. MAIN FRAME DOES NOT LOAD IN MANUAL MODE (MODEL B ONLY)
(continued).
HYDRAULICCABINET
COVER
CONTINUITY TEST
CAUTION
Electrical power must be shut off
be checked. Failure to comply with
this caution may result in damage
to test equipment or electrical sys-
tem.
POSITION
(1) Remove six screws and flatwashers
1
from hydraulic cabinet cover and
MAIN FRAME LOAD
remove cover.
SOLENOID
(2) Remove right hand (J3) and left hand
CONNECTOR
(J4), 40-pin connectors from digital
POSITION
2
contoller.
NOTE
POSITION 2
J3
POSITION
A reading of infinity indicates an
32
POSITION
open circuit.
35
POSITION
33
controller wiring harness connector,
(P2), position "2", and (J4), position
POSITION
(5) Connect multimeter between (P2),
1
position "3", and (J4), position "35".
(6) Connect multimeter between (P2),
J4
position "4", and (J4), position "33".
(7) Connect multimeter between (J3),
position "2", and main frame load
P2
(8) Connect multimeter between (J3),
position "2", and main frame load
POSITION 4
POSITION 3
Change 1
4-265
9