TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
12. HOOK ARM DOES NOT UNLOAD IN MANUAL MODE (MODEL B ONLY) (continued).
HYDRAULICCABINET
COVER
CONTINUITY TEST
CAUTION
Electrical power must be shut off
be checked. Failure to comply with
this caution may result in damage
to test equipment or electrical sys-
tem.
(1) Remove five screws and flatwashers
from hydraulic cabinet cover and
remove cover.
POSITION
(2) Remove right hand (J3) and left hand
1
(J4), 40-pin connectors from digital
HOOK ARM UNLOAD
contoller.
SOLENOID
(3) Remove unload solenoid connector
CONNECTOR
from unload solenoid valve.
POSITION
2
NOTE
J3
POSITION 3
POSITION
33
A reading of infinity indicates an
POSITION
open circuit.
35
POSITION
33
controller wiring harness connector,
(P2), position "2", and (J4), position
POSITION
(6) Connect multimeter between (P2),
1
position "3", and (J4), position "35".
(7) Connect multimeter between (P2),
J4
position "4", and (J4), position "33".
(8) Connect multimeter between (J3),
position "3", and hook arm unload
P2
(9) Connect multimeter between (J3),
position "33", and hook arm unload
POSITION 4
POSITION 3
4-449241
2- - 55
36..4
Change 1