TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
11. HOOK ARM DOES NOT LOAD IN MANUAL MODE (MODEL B ONLY) (continued).
HYDRAULICCABINET
CONTINUITY TEST
COVER
CAUTION
Electrical power must be shut off
be checked. Failure to comply with
this caution may result in damage
to test equipment or electrical sys-
tem.
(1) Remove five screws and flatwashers
from hydraulic cabinet cover and
remove cover.
HOOK ARM LOAD
(2) Remove right hand (J3) and left hand
SOLENOID
(J4), 40-pin connectors from digital
CONNECTOR
contoller.
POSITION 1
POSITION 2
NOTE
A reading of infinity indicates an
open circuit.
J3
POSITION 4
POSITION
34
POSITION
controller wiring harness connector,
35
(P2), position "2", and (J4), position
POSITION
33
(5) Connect multimeter between (P2),
position "3", and (J4), position "35".
(6) Connect multimeter between (P2),
POSITION
1
position "4", and (J4), position "33".
(7) Connect multimeter between (J3),
J4
position "4", and hook arm load
(8) Connect multimeter between (J3),
position "34", and hook arm load
P2
POSITION 4
POSITION 3
Change 1
44295.19
- - 14 4
4-2 5