4-12. UNIT TROUBLESHOOTING (continued).
11. HOOK ARM DOES NOT LOAD IN MANUAL MODE (continued).
CONTINUITY TEST
CAUTION
Electrical power must be shut
off from circuit before continu-
ity can be checked. Failure to
comply with this caution may
P9
result in damage to test equip-
ment or electrical system.
(1) Disconnect remote control cable
from components.
NOTE
A reading of infinity indicates an
REMOTE CONTROL
open circuit.
CABLE
P8
end of wire, and check multimeter
between position G on chassis end
and position J on remote control
between position J on chassis end
and position E on remote end.