TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
8.
OIL TEMPERATURE LIGHT DOES NOT OPERATE PROPERLY (MODEL A ONLY)
(continued).
CONTINUITY TEST
CAUTION
Electrical power must be shut off
be checked. Failure to comply
with this caution may result in dam-
age to test equipment or electrical
system.
NOTE
WIRING REMOVED FOR CLARITY
A reading of infinity indicates an
open circuit.
(2) Connect multimeter to terminals at
MAIN JUNCTION
each end of wire, and check multi-
BOX CONNECTOR
(J4)
main junction box connector (J4),
position N, and terminal strip,
position 2. Also check between main
junction box connector (J4), position
P, and terminal strip, position 1.
NOTE
Any reading besides infinity indi-
cates a grounded wire.
of wire and connect to chassis
ground.
4-143
Change 1