TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
7.
HOURMETER DOES NOT OPERATE (MODEL A ONLY) (continued).
ACCESS
COVER
VOLTAGE TEST
(1) Remove four screws and
from heater compartment.
(2) Remove cab control box
connector (P2) from cab control
box.
CAB
(3) Turn engine start switch to ON
CONTROL
position.
BOX
(4) Set multimeter to voltage
position.
(5) Place positive (+) probe of
control box connector (J2).
CAB CONTROL BOX
(6) Place negative (-) probe of
CONNECTOR (J2)
ground, and check multimeter
for voltage reading.
(7) Turn engine start switch to OFF
position.
CAB CONTROL BOX
CONNECTOR (P2)
4-125
Change 1