TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
5.
HAND-HELD SPOTLIGHT DOES NOT OPERATE (continued).
WORKLIGHT SWITCH TEST
(1) Remove eight screws and side
panel from heater compartment.
(2) Move cab worklight switch to
the ON position.
CAUTION
Electrical power must be shut
off from circuit before conti-
nuity can be checked. Fail-
ure to comply with this cau-
WORKLIGHT
tion may result in damage to
SWITCH
test equipment or electrical
TERMINALS
system.
(3) Set multimeter to ohms
position.
NOTE
A reading of infinity indicates
a faulty switch.
worklight switch terminals, and
WORKLIGHT
SWITCH
TERMINALS
(SWITCH REMOVED FROM PANEL FOR CLARITY)
4-101