TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
4.
MAIN FRAME WORKLIGHT DOES NOT OPERATE (MODEL A ONLY) (continued).
CONTINUITY TEST
CAUTION
Electrical power must be shut off
be checked. Failure to comply
with this caution may result in dam-
age to test equipment or electrical
SUPPLY
system.
HARNESS
CONNECTOR
(J1)
NOTE
Tag and mark connector before re-
moving.
(1) Disconnect (9-pin) linking harness
connector from cab control box.
(2) Set multimeter to ohms position.
NOTE
A reading of infinity indicates an
(9-PIN) LINKING
open circuit.
HARNESS
CONNECTOR (J5)
of wire, and check multimeter for
linking harness connector, position G,
and supply harness connector,
position H.
NOTE
Any reading besides infinity indi-
cates a grounded wire.
of wire and connect to chassis
ground.
Change 1
4-87