TM 5-5420-234-14&P
4-12. UNIT TROUBLESHOOTING (continued).
3.
ENGINE HIGH IDLE DOES NOT OPERATE (MODEL B ONLY) (continued).
HYDRAULICCABINET
COVER
CONTINUITY TEST
CAUTION
Electrical power must be shut off
be checked. Failure to comply with
this caution may result in damage
to test equipment or electrical sys-
tem.
(1) Remove five screws and flatwashers
from hydraulic cabinet cover and
remove cover.
(2) Remove left hand (J4), 40-pin
connectors from digital contoller.
(3) Remove cap from right hand (J8A),
remote control cable connector.
NOTE
A reading of infinity indicates an
J4
POSITION
open circuit.
12
(5) Connect multimeter between (J4),
position "12," and (J8A), position "K".
J8A
POSITION
K
Change 1
4-75
81